Commercial and Industrial Energy Storage Cabinet
D-Cube-E50/100
- Ultimate Safety
- Adopts lithium iron phosphate cells with inherently safe and reliable chemistry
- Innovative BMS with refined sampling enables real-time cell health monitoring and alarms
- AC and DC two-level surge protection, equipped with short circuit, over/under voltage, over current, reverse connection and other multi-layer protections
- High-Efficiency Power Generation
- Supports PV 200% over-sizing design to boost generation revenue
- 4 MPPT channels, each supporting 20A high-current input
- Wide voltage range of 150-850V, maintaining strong output even under low light
- Intelligent Coordination
- 10ms seamless switch to off-grid mode ensures uninterrupted power supply for critical loads
- Smart linkage with diesel generator enables fully automatic backup power without manual intervention
- Supports APP real-time monitoring and remote OTA upgrade for easier system O&M
- Flexible Adaptation
- Supports flexible applications across multiple scenarios including self-consumption, peak-valley arbitrage, and backup power
- Battery capacity of 100kWh, with depth of discharge (DOD) up to 95%
- Wide operating temperature range of -25~60℃, IP66 protection, suitable for high altitudes up to 4000m
Specifications
Battery Parameters
| Battery Type | Lithium Iron Phosphate (LFP) |
| Cell Capacity | 3.2/280V/Ah |
| Cell Configuration | 1P112S |
| Nominal Energy | 100.352kWh |
| Nominal Voltage | 358.4V |
| Voltage Range | 280~408.8V |
| Max Charge/Discharge Current | 140A |
| Depth of Discharge (DOD) | 95% |
| Cooling Method | Air cooling |
| Fire Protection | Pack-level aerosol |
| Protection Level | IP20 |
| Operating Temperature | -20~60℃ |
| Relative Humidity | ≤85%RH |
Electrical Parameters
| Recommended Max Input Power | 100kW |
| Max DC Input Voltage | 1000V |
| Nominal DC Input Voltage | 600V |
| Startup Voltage | 180V |
| MPPT Voltage Range | 150~850V |
| Number of MPPTs | 4 |
| Max Input Current | 4×40A |
| Max Short-Circuit Current | 4×60A |
| Max Number of Input Strings | 8 |
| Nominal Output Power | 50kW |
| Max Apparent Output Power | 50kVA |
| Nominal Grid Voltage | 3/N/PE, 380/400V |
| Nominal Output Frequency | 50/60Hz |
| Total Harmonic Distortion of Voltage (THDv) | <3 (under linear load)% |
Mechanical Parameters
| Protection Level | IP66 |
| Cooling Method | Smart air cooling |
| Night Mixed-Mode Self-Consumption | <35W |
| Dimensions (W×H×D) | 530×880×290mm |
| Weight | 73kg |
Environmental Parameters
| Operating Temperature | -25~60℃ |
| Relative Humidity | ≤100%RH |
| Altitude | 4000 (derating above 2000 m)m |
Communication
| Communication Method | CAN, RS485, Ethernet, Wi-Fi (optional), Cellular (optional), LAN (optional) |
Version Information
| Datasheet Version | 1.2 |