D-Cube-S125/261-ASEAN
Commercial and Industrial Energy Storage Cabinet

D-Cube-S125/261-ASEAN

  • Flexible & Efficient
    • Integrated AC and DC system design for more flexible deployment and configuration
    • No parallel circulating current design, significantly reducing energy loss
    • Inverter maximum efficiency ≥98.5%, system peak efficiency ≥88%
  • Safe & Stable
    • Three-level fire protection system for comprehensive system safety
    • Precision liquid cooling temperature control with cell temperature difference ≤3°C for long-term stable operation
    • Equipped with combustible gas, smoke, and thermal detectors along with aerosol fire extinguishing devices
  • Intelligent Collaboration
    • Smart switching strategy supporting peak-valley arbitrage, dynamic capacity expansion, and renewable energy consumption
    • Local and cloud monitoring integration for rapid digital diagnostics and intelligent inspection
    • Closed-loop safety logic with 3S and EMS collaboration for full-link system safety
  • High-Density Integration
    • 125kW/261kWh integrated energy storage cabinet with higher integration level
    • Adopting LFP cells with battery pack string IP260S for longer cycle life
    • Supports IP54 protection with operating temperature of -20℃~55℃, adaptable to multiple scenarios

Specifications

Electrical Parameters
AC Rated Power125kW
AC Maximum Power137.5kW
AC Rated Voltage380Vac
AC Allowable Voltage Range340~460Vac
Rated Frequency50Hz
Adjustable Power Factor Range-1 (leading) ~ 1 (lagging)
Total Harmonic Distortion<3% (at rated output power)
AC Input Mode3P+N+PE
Battery TypeLFP (Lithium Iron Phosphate)
Battery Cell Capacity3.2V/Ah
Battery Cell ConfigurationIP260S
Nominal Energy261kWh
Nominal Voltage832V
Voltage Range689~949V
Efficiency
Inverter Maximum Efficiency≥98.5%
System Maximum Efficiency≥88%
Charge/Discharge Rate (C-rate)P ≤ 0.5
Protection
DC Input ProtectionSupported
Inverter AC ProtectionSupported
AC Output ProtectionSupported
Overvoltage ProtectionDC Type II / AC Type II
Fire ProtectionCombustible gas detector, thermal detector, smoke detector, alarm horn, aerosol fire suppression device
Fire Protection LevelLevel 3 fire protection system
Battery Temperature BalancingCell-to-cell temperature difference ≤ 3℃
Communication
Communication ProtocolRS485/CAN/Ethernet
Mechanical Parameters
Dimensions (W × D × H)1150 × 1450 × 2400mm
Weight2.5t
Cable Entry/Exit MethodBottom entry / Bottom exit
Environmental Parameters
Operating Temperature Range-20 ≤ T ≤ 55 (derating above 50℃)℃
Humidity Range≤95%
Altitude≤ 3000 (derating above 2000)m
Protection LevelIP54
Cooling MethodLiquid cooling
Version Information
Datasheet Version2.4